Integrated Frisker

Model Number:

PTI-IFW


PTI-IFW

Integrated Frisker

  • Integrated, lightweight design simplifies frisking
  • High-impact plastic with water resistant rubber seals
  • Employs standard 15.51 cm2 GM pancake detector
  • Displays in mR/hr, uSv/h, dpm, Bq, cpm, or cps
  • Dead-time correction (DTC) allows Gamma measurements
  • Up to 500 mR/hr or up to 1999 uSv/h
  • Simple three button operation
  • Count rate, dose/exposure, and counting alarms 
  • Automatic display backlight
  • Bright red flashing alarm LED
  • Includes wrist strap, clear pancake cover & ludlum lanyard
  • Detector: Pancake GM detector, stainless steel screen (79% open)
  • Window Area: Active: 15.51 cm2 (2.4 in2) Open: 12.26 cm2 (1.9 in2)
  • Efficiency: Alpha: 239Pu: 11%, 99Tc: 18%, 32P: 32% Beta: 14C : 2%, 90Sr/Y : 22%, 125I : 0.2% Gamma: 137Cs : 5.5 cps per μSv/hr (3300 cpm per mR/hr), 99mTc : ≤ 1% 
  • LCD Display: 3½ digit LCD with large 12.7 mm (0.5 in.) digits, low-battery indicator, MAX, ALARM Units: (k)cps, (k)cpm, (k)dpm, (k)Bq, mR/hr, µSv/h, Bq, dpm
  • Range: 0.1 cps to 19.9 kcps, 1 cpm to 999 kcpm, 0.0 to 1000 mR/hr, 0.01 to 1999 µSv/h, 0.1 to 19.9 kBq
  • Backlight: Built-in ambient light sensor automatically activates low-power LED backlight, or may be configured for 'Continuous On' operations (will reduce battery life)
  • Controls: ON/OFF/Quiet , Mode: Alternates between: Normal : count rate, Max : captures peak rate, Scaler : user-selectable preset count time from 0 to 20 min., Each mode is separately programmable so it can be active or turned off.
  • Response Time: User-selectable from 1 to 60 s, or automatic FAST or SLOW 
  • Resolving Time: Approximately 110 µs as defined by IEC 60325
  • Alarms: Count rate and scaler alarm setpoints adjustable over the display range
  • Zero Protection: After 60 s of no pulses from detector, unit will flash a zero reading and the alarm audio will be triggered
  • Overload: High rate saturation protection, indicated by flashing display and audio alarm, prevents false display of lower count rates 
  • Click Audio: Greater than 60 dB at 0.6 m (2 ft.)
  • Temperature Range: -20 to 50 °C (-4 to 122 °F) May be certified for operation from -40 to 65 °C (-40 to 150 °F)
  • Power: Two "AA" batteries
  • Battery Life:  Approximately 1000 hours of operations (as low as 500 hours with backlight configured for 'Continuous On'), 16-hour low battery warning